Select values from the drop down lists or make appropriate selections to configure the part number.
Nozzle Size
-- Pick an Option --
00 (Vacuum Pump System Only; Large Flow, N.C.)
03 [Nominal Nozzle Size: ø0.3mm; Large Flow, N.C.: 50.8psi (0.34MPa); Latching: 58psi (0.4MPa)]
04 [Nominal Nozzle Size: ø0.4mm; Large Flow, N.C.: 50.8psi (0.35MPa); Latching: 65.3psi (0.45MPa)]
05 [Nominal Nozzle Size: ø0.5mm; Large Flow, N.C.: 50.8psi (0.35MPa)]
06 [Nominal Nozzle Size: ø0.6mm; Large Flow, N.C.: 72.5psi (0.5MPa)]
Body
-- Pick an Option --
1 [Single Unit; Port Specification: PV, PD Common Port (PV=PD)]
2 [Single Unit; Port Specification: PV, PD Individual Port (PV≠PD)]
3 [For Manifold; Port Specification: No Distinction]
Exhaust
-- Pick an Option --
0 (For Vacuum Pump System, w/o Silencer)
1 (Silencer Exhaust, Individual Exhaust)
2 (Port Exhaust, Individual Exhaust)
Valve Combination
-- Pick an Option --
K1 (Supply Valve: N.C.; Release Valve: N.C.)
J1 (Supply Valve: N.C.; Release Valve: None)
Q1 (Supply Valve: Latching, Positive Common; Release Valve: Normally Closed)
Q2 (Latching, Positive Common; Release Valve: None)
Rated Voltage
-- Pick an Option --
5 (24VDC)
6 (12VDC)
Electrical Entry
-- Pick an Option --
L (L-Type Plug Connector w/Lead Wire)
LO (L-Type Plug Connector w/o Connector)
M (M-Type Plug Connector w/Lead Wire)
MO (M-Type Plug Connector w/o Connector)
Manual Override
-- Pick an Option --
Non-Locking Push Type
B (Locking Type, Tool Required, Semi-Standard)
Sensor/Switch Specifications
-- Pick an Option --
w/o Pressure Sensor or Vacuum Pressure Switch
P1 [Pressure Sensor: 0 to -14.6 (0 to -101), Output: 1 to 5V, Accuracy ±2% F.S. or Less]
P3 [Pressure Sensor: -14.5 to 14.5 (-100 to 100); Output: 1 to 5V, Accuracy ±2% F.S. or Less]
EA [Vacuum Pressure Switch: 0 to -14.5 (0 to -101), NPN 2 Outputs, w/Unit Switching Function]
EAM [Vacuum Pressure Switch: 0 to -14.5 (0 to -101), SI Unit Only]
EAP [Vacuum Pressure Switch: 0 to -14.5 (0 to -101), NPN 2 Outputs, w/Unit Switching Function (Initial Value psi)]
EB [Vacuum Pressure Switch: 0 to -14.5 (0 to -101), PNP 2 Outputs, w/Unit Switching Function]
EBM [Vacuum Pressure Switch: 0 to -14.5 (0 to -101), PNP 2 Outputs, SI Unit Only]
EBP [Vacuum Pressure Switch: 0 to -14.5 (0 to -101), PNP 2 Outputs, w/Unit Switch Function (Initial Value psi)]
FA [Vacuum Pressure Switch: -14.5 to 14.5 (-100 to 100), NPN 2 Outputs, w/Unit Switching Function]
FAM [Vacuum Pressure Switch: -14.5 to 14.5 (-100 to 100), NPN 2 Outputs, w/SI Unit Only]
FAP [Vacuum Pressure Switch: -14.5 to 14.5 (-100 to 100), NPN 2 Outputs, w/Unit Switching Function (Inital Valve psi)]
FB [Vacuum Pressure Switch: -14.5 to 14.5 (-100 to 100), PNP 2 Outputs, w/Unit Switching Function]
FBM [Vacuum Pressure Switch: -14.5 to 14.5 (-100 to 100), PNP 2 Outputs, w/SI Unit Only]
FBP [Vacuum Pressure Switch: -14.5 to 14.5 (-100 to 100), PNP 2 Outputs, w/Unit Switching Function (Inital Valve psi)]
Pressure Switch Lead Wire
-- Pick an Option --
w/o Lead Wire w/Connector
G [Lead Wire w/Connector & Connector Cover, Lead Wire Length 78.8" (2m)]
Vacuum Port
-- Pick an Option --
C2 (Straight ø2mm One-Touch Fitting)
C4 (Straight ø4mm One-Touch Fitting)
N1 (Straight ø1/8" One-Touch Fitting)
N3 (Straight ø5/32" One-Touch Fitting)
L2 (Elbow ø2mm One-Touch Fitting)
L4 (Elbow ø4mm One-Touch Fitting)
LN1 (Elbow ø1/8" One-Touch Fitting)
LN3 (Elbow ø5/32" One-Touch Fitting)
Option
-- Pick an Option --
None
B (Bracket for Single Unit - Not Assembled)
BK (B+K)
K (Screwdriver Handling Type Vacuum Break Needle)
Options in: Gray are not compatible with other selected option value. Red conflict with another selected option value. Amber are not recommended.